在线超碰av,天天操天天摸天天射,免费的爱爱视频,情侣av在线,一级片中文字幕,2022国产毛片大全,精品亚洲大全

歡迎來(lái)到瑞昌明盛自動(dòng)化設(shè)備有限公司官網(wǎng)!

產(chǎn)品展示
聯(lián)系我們

聯(lián)系人:麥女士

手機(jī):+86 15270269218

電話:

Q Q:3136378118

郵箱:stodcdcs@gmail.com

地址:江西省九江市瑞昌市東益路23號(hào)賽湖農(nóng)商城401號(hào)

DO479使用區(qū)域
DO479使用區(qū)域
DO479使用區(qū)域
DO479使用區(qū)域
DO479使用區(qū)域
DO479使用區(qū)域

型號(hào):DO479

類別:貝加萊(B&R)

聯(lián)系人:麥女士

手機(jī):+86 15270269218

電話:+86 15270269218

Q Q:3136378118

郵箱:stodcdcs@gmail.com

地址:江西省九江市瑞昌市東益路23號(hào)賽湖農(nóng)商城401號(hào)


在線咨詢


DO479
安裝說(shuō)明機(jī)架安裝1。根據(jù)10頁(yè)的安裝注意事項(xiàng),選擇并準(zhǔn)備適當(dāng)?shù)陌惭b位置。2、使用標(biāo)準(zhǔn)機(jī)架安裝硬件將設(shè)備安裝在機(jī)架中(驅(qū)動(dòng)器入口朝外)。3、將電源線的一端連接到電源插座,另一端連接到正確接地的115/230 VAC、50-60 Hz插座。4、打開(kāi)電源。系統(tǒng)將啟動(dòng)到已安裝的操作系統(tǒng)。通過(guò)軟盤驅(qū)動(dòng)器或CD-ROM安裝應(yīng)用軟件。圖2-19。安裝機(jī)架安裝硬件帶滑軌的機(jī)架安裝1。將設(shè)備放置在堅(jiān)固的工作面上,并斷開(kāi)所有電纜和跳線與設(shè)備的連接。2、將提供的Xycom滑軌(按訂單號(hào)1600–RMS單獨(dú)訂購(gòu))連接到裝置上(見(jiàn)圖2–20)。3、使用標(biāo)準(zhǔn)機(jī)架安裝硬件將裝置牢固安裝在機(jī)架中,使驅(qū)動(dòng)器檢修門朝外。將導(dǎo)軌安裝螺釘扭轉(zhuǎn)至35 in/lbs.5。重新連接所有電纜和跳線。15帶奔騰4的1600系列2章-安裝圖2-20。安裝可選的滑軌系統(tǒng)電源在1600的輸入交流電源線上使用隔離變壓器總是一個(gè)好主意。在重型設(shè)備可能會(huì)在交流線路上引入噪聲的情況下,尤其需要使用隔離變壓器。隔離變壓器也可用作降壓變壓器,以將進(jìn)線電壓降低至所需水平。變壓器應(yīng)具有足夠的額定功率(單位為伏安),以充分供應(yīng)負(fù)載。正確接地對(duì)于所有安全的電氣裝置至關(guān)重要。請(qǐng)參閱相關(guān)的聯(lián)邦、州、省和地方電氣規(guī)范,這些規(guī)范提供了電氣部件安全接地所需的導(dǎo)線尺寸和類型、顏色代碼和連接等數(shù)據(jù)。該規(guī)范規(guī)定,接地路徑必須是性的(無(wú)焊料)、連續(xù)的,并且能夠在系統(tǒng)中以小阻抗安全地傳導(dǎo)接地故障電流(所需的小導(dǎo)線為18 AWG,1 mm)。遵守以下做法:在外殼入口點(diǎn)將地線(P.E.或保護(hù)接地)與電源線分開(kāi)。為盡量減少外殼內(nèi)的地線長(zhǎng)度,將接地參考點(diǎn)定位在工廠電源入口附近。所有電氣機(jī)架或底盤和機(jī)器元件應(yīng)在預(yù)計(jì)會(huì)產(chǎn)生高電氣噪聲的安裝中接地。用接地棒將機(jī)箱接地,或連接到附近的接地結(jié)構(gòu)上,如鋼支撐梁。每個(gè)不同的設(shè)備應(yīng)連接到具有低阻抗電纜的“星形”配置中的單個(gè)接地點(diǎn)。從機(jī)箱與外殼接觸的區(qū)域刮去油漆和其他不導(dǎo)電材料。除了通過(guò)安裝螺栓或螺柱進(jìn)行接地連接外,還應(yīng)使用一英寸的金屬編織物或尺寸為#8 AWG的電線連接每個(gè)機(jī)箱和安裝螺栓或螺柱處的外殼。
DO479使用區(qū)域 DO479使用區(qū)域 DO479使用區(qū)域
Mounting Instructions Rack Mounting 1. Select and prepare an appropriate mounting location according to the Mounting Considerations on page 10. 2. Install the unit in the rack (with drive access facing outward) using the standard rack-mounting hardware. 3. Attach one end of the power cord to the power receptacle and the other end to a properly grounded 115/230 VAC, 50-60 Hz outlet. 4. Turn on the power. The system will boot up to the installed operating system. 5. Install application software via a floppy drive or CD-ROM. Figure 2–19. Installing Rack Mounting Hardware Rack Mounting with Slide Rails 1. Place the unit on a solid work surface and disconnect all cables and cords from the unit. 2. Attach the provided Xycom slide rails (ordered separately by order number 1600–RMS) to the unit (see Figure 2–20). 3. Install the unit securely in the rack with standard rack-mounting hardware so that the drive access door faces outward. 4. Torque the rail-mounting screws to 35 in/lbs. 5. Reconnect all cables and cords. 15 1600 Series with Pentium 4 Chapter 2 – Installation Figure 2–20. Installing Optional Slide Rails System Power It is always a good idea to use isolation transformers on the incoming AC power line to the 1600. An isolation transformer is especially desirable in cases where heavy equipment is likely to introduce noise onto the AC line. The isolation transformer can also serve as a step-down transformer to reduce the incoming line voltage to a desired level. The transformer should have a sufficient power rating (units of volt-amperes) to supply the load adequately. Proper grounding is essential to all safe electrical installations. Refer to the relevant Federal, State, Provincial, and local electric codes that provide data such as the size and types of conductors, color codes and connections necessary for safe grounding of electrical components. The code specifies that a grounding path must be permanent (no solder), continuous, and able to safely conduct the ground-fault current in the system with minimal impedance (minimum wire required is 18 AWG, 1 mm). Observe the following practices:  Separate ground wires (P.E. or Protective Earth) from power wires at the point of entry to the enclosure. To minimize the ground wire length within the enclosure, locate the ground reference point near the point of entry for the plant power supply.  All electrical racks or chassis and machine elements should be Earth Grounded in installations where high levels of electrical noise are expected. Ground the chassis with a ground rod or attach to a nearby Earth structure such as a steel support beam. Each different apparatus should be connected to a single Earth Ground point in a “star” configuration with low impedance cable. Scrape away paint and other nonconductive material from the area where a chassis makes contact with the enclosure. In addition to the ground connection made through the mounting bolt or stud, use a one-inch metal braid or size #8 AWG wire to connect between each chassis and the enclosure at the mounting bolt or stud.



相關(guān)產(chǎn)品