Moulded-case circuit-breaker: SACE Tmax XT
1.1 Circuit-breaker nameplates
IEC 60947-2
ABB SACE
Italy
on
off
160
XT1B
I
In = 160A TEST
SACE Tmax
Rated operational
voltage Ue
Tmax XT1B160
Ue (V)
Icu (kA)
Ics
Cat A
(% Icu)
Ue=690V AC/500V DC Ui=800V Uimp=8kV S/N:
230
25
100 100
18
415 525
100
6 3
100
690
50-60Hz 2P in series
250
18
100
Tmax
Cat A
Rated impulse
withstand voltage
Uimp; i.e. the peak
value of impulse
voltage which the
circuit-breaker can
withstand under
specified test
conditions.
Rated insulation
voltage Ui; i.e. the
maximum r.m.s. value
of voltage which the
circuit-breaker is
capable of
withstanding at the
supply frequency
under specified test
conditions.
Rated ultimate shortcircuit breaking capacity
(Icu) and rated service
short-circuit breaking
capacity (Ics) at
different voltage values.
According to the
international Standard
IEC 60947-2, the circuit
breakers can be divided
into Category A, i.e.
without a specified
short-time withstand
current rating, or
Category B, i.e. with a
specified short-time
withstand current rating.
CE marking affixed on
ABB circuit-breakers to
indicate compliance
with the following CE
directives:
“Low Voltage Directive”
(LVD) no. 2006/95/CE
“Electromagnetic
Compatibility Directive”
(EMC) no. 89/336 EEC.
Compliance with the
international
Standard
IEC 60947-2:
“Low-Voltage
switchgear and
controlgear-Circuitbreakers”.
Size
1
2
3
4
5
6
7
CIRCUIT-BREAKER TYPE
Size
160 A
250 A
Rated ultimate short-circuit
breaking capacity at 415 Vac
B = 18 kA (XT1)
C = 25 kA (XT1)
N = 36 kA
S = 50 kA
H = 70 kA
L = 120 kA (XT2-XT4)
V = 150 kA (XT2-XT4)
Size
1
2
3
4
Series
XT
Seriel number
In rated current
ABB | Protection and control devices 29
1 Protection and control devices
Moulded-case circuit-breaker: Tmax T
ASDC008046F0201
Tmax T2L160
Ue (V)
Icu (kA)
Ics
Cat A
(% Icu)
Iu=160A Ue=690V Ui=800V Uimp=8kV IEC 60947-2
230
150
75 75
85
400/415 440
75
75 50
75
500 690
10
75
250
85
75
500
85
75
Made in Italy
by ABB SACE
2 P 3 P in series 50-60Hz
Rated impulse
withstand voltage
Uimp; i.e. the peak
value of impulse
voltage which the
circuit-breaker can
withstand under
specified test
conditions.
Rated uninterrupted
current Iu
Rated operational
voltage Ue
Rated insulation
voltage Ui; i.e. the
maximum r.m.s. value
of voltage which the
circuit-breaker is
capable of
withstanding at the
supply frequency
under specified test
conditions.
Rated ultimate shortcircuit breaking capacity
(Icu) and rated service
short-circuit breaking
capacity (Ics) at
different voltage values.
According to the
international Standard
IEC 60947-2, the circuit
breakers can be divided
into Category A, i.e.
without a specified
short-time withstand
current rating, or
Category B, i.e. with a specified short-time
withstand current rating.
CE marking affixed on
ABB circuit-breakers to
indicate compliance
with the following CE
directives:
“Low Voltage Directive”
(LVD) no. 2006/95/CE
“Electromagnetic
Compatibility Directive”
(EMC) no. 89/336 EEC.
Compliance with the
international
Standard
IEC 60947-2:
“Low-Voltage
switchgear and
controlgear-Circuitbreakers”.
26390582-BL DSTK128使用手冊 26390582-BL DSTK128使用手冊 26390582-BL DSTK128使用手冊
塑殼斷路器:SACE Tmax XT
1.1斷路器銘牌
IEC 60947-2
薩奇神甫
意大利
在…上
關(guān)
160
XT1B

In=160A測試
SACE Tmax
額定運(yùn)行
電壓Ue
Tmax XT1B160
Ue(五)
重癥監(jiān)護(hù)病房(kA)
Ics
貓A
(%重癥監(jiān)護(hù)病房)
Ue=690V AC/500V DC Ui=800V Uimp=8kV序列號(hào):
230
25
100 100
18
415 525
100
6 3
100
690
50-60Hz 2P串聯(lián)
250
18
100
Tmax
貓A
額定脈沖
耐壓
Uimp;i、 e.山頂
沖動(dòng)的價(jià)值
電壓
斷路器can
抵擋
指定測試
條件
額定絕緣
電壓Ui;i、 e.問題
大r.m.s.值
電壓
斷路器是
能夠
頂住
供電頻率
在規(guī)定的測試下
條件
額定極限短路開斷能力
(Icu)和額定服務(wù)
短路斷路
容量(Ics)
不同的電壓值。
根據(jù)
國際標(biāo)準(zhǔn)
IEC 60947-2,電路
斷路器可以分為兩部分
屬于A類,即。
沒有指定的
短時(shí)耐受
當(dāng)前額定值,或
B類,即a類
指定的短期
承受額定電流。
貼上CE標(biāo)志
ABB斷路器至
表示遵守
以下是CE
指令:
“低壓指令”
(LVD)第2006/95/CE號(hào)
“電磁的
“兼容性指令”
(EMC)第89/336號(hào)EEC。
遵守
國際的
標(biāo)準(zhǔn)
IEC 60947-2:
“低電壓
開關(guān)設(shè)備和
“控制設(shè)備斷路器”。
大小
1.
2.
3.
4.
5.
6.
7.
斷路器類型
大小
160 A
250安
額定極限短路
415伏交流電時(shí)的分?jǐn)嗄芰?br />B=18kA(XT1)
C=25kA(XT1)
N=36 kA
S=50kA
H=70 kA
L=120kA(XT2-XT4)
V=150 kA(XT2-XT4)
大小
1.
2.
3.
4.
系列
XT
序列號(hào)
在額定電流下
ABB |保護(hù)和控制裝置29
1.保護(hù)和控制裝置
塑殼斷路器:Tmax T
ASDC008046F0201
Tmax T2L160
Ue(五)
重癥監(jiān)護(hù)病房(kA)
Ics
貓A
(%重癥監(jiān)護(hù)病房)
Iu=160A Ue=690V Ui=800V Uimp=8kV IEC 60947-2
230
150
75 75
85
400/415 440
75
75 50
75
500 690
10
75
250
85
75
500
85
75
意大利制造
薩克神甫
2 P 3 P串聯(lián)50-60Hz
額定脈沖
耐壓
Uimp;i、 e.山頂
沖動(dòng)的價(jià)值
電壓
斷路器can
抵擋
指定測試
條件
額定不間斷
當(dāng)前Iu
額定運(yùn)行
電壓Ue
額定絕緣
電壓Ui;i、 e.問題
大r.m.s.值
電壓
斷路器是
能夠
頂住
供電頻率
在規(guī)定的測試下
條件
額定極限短路開斷能力
(Icu)和額定服務(wù)
短路斷路
容量(Ics)
不同的電壓值。
根據(jù)
國際標(biāo)準(zhǔn)
IEC 60947-2,電路
斷路器可以分為兩部分
屬于A類,即。
沒有指定的
短時(shí)耐受
當(dāng)前額定值,或
B類,即具有指定的短時(shí)間
承受額定電流。
貼上CE標(biāo)志
ABB斷路器至
表示遵守
以下是CE
指令:
“低壓指令”
(LVD)第2006/95/CE號(hào)
“電磁的
“兼容性指令”
(EMC)第89/336號(hào)EEC。
遵守
國際的
標(biāo)準(zhǔn)
IEC 60947-2:
“低電壓
開關(guān)設(shè)備和
“控制設(shè)備斷路器”。