在线超碰av,天天操天天摸天天射,免费的爱爱视频,情侣av在线,一级片中文字幕,2022国产毛片大全,精品亚洲大全

歡迎來(lái)到瑞昌明盛自動(dòng)化設(shè)備有限公司官網(wǎng)!

產(chǎn)品展示
聯(lián)系我們

聯(lián)系人:麥女士

手機(jī):+86 15270269218

電話:

Q Q:3136378118

郵箱:stodcdcs@gmail.com

地址:江西省九江市瑞昌市東益路23號(hào)賽湖農(nóng)商城401號(hào)

YL681001-AF產(chǎn)品尺寸
YL681001-AF產(chǎn)品尺寸
YL681001-AF產(chǎn)品尺寸
YL681001-AF產(chǎn)品尺寸
YL681001-AF產(chǎn)品尺寸
YL681001-AF產(chǎn)品尺寸

型號(hào):YL681001-AF

類別:ABB

聯(lián)系人:麥女士

手機(jī):+86 15270269218

電話:+86 15270269218

Q Q:3136378118

郵箱:stodcdcs@gmail.com

地址:江西省九江市瑞昌市東益路23號(hào)賽湖農(nóng)商城401號(hào)


在線咨詢


電容器組分為
幾個(gè)步驟,直接安裝在主配電盤中;使用
只有在吸收
中,無(wú)功能量的消耗是相當(dāng)有規(guī)律的。
集中式PFC的主要缺點(diǎn)是
PFC裝置下游的安裝尺寸必須考慮
計(jì)算負(fù)荷所需的全部無(wú)功功率。
3.3保護(hù)斷路器和
電容器組的切換
低壓電容器組保護(hù)和切換用斷路器
應(yīng):
1、承受連接和連接時(shí)產(chǎn)生的瞬態(tài)電流
斷開銀行的連接。特別是瞬時(shí)磁場(chǎng)和
電子脫扣器不得因這些峰值電流而跳閘;
2、承受由電壓引起的周期性或性過(guò)電流
諧波和容量額定值的公差(+15%);
3、執(zhí)行大量空載和有載操作,也包括高負(fù)載
頻率
4、與任何外部設(shè)備(接觸器)協(xié)調(diào)。
此外,斷路器的接通和斷開容量必須為
足以滿足裝置的短路電流值。
IEC 60831-1和60931-1標(biāo)準(zhǔn)規(guī)定:
-電容器的有效電流值通常應(yīng)高達(dá)130%
其額定電流Irc(由于可能存在電壓諧波)
網(wǎng)絡(luò));
-對(duì)于高達(dá)100 kvar的組,電容的容差為10%,容差為5%
對(duì)于超過(guò)100 kvar的組,允許使用。
YL681001-AF產(chǎn)品尺寸 YL681001-AF產(chǎn)品尺寸 YL681001-AF產(chǎn)品尺寸
automatic units with capacitor banks divided into several steps, directly installed in the main distribution switchboards; the use of a permanently connected capacitor bank is only possible if the absorption of reactive energy is fairly regular throughout the day. The main disadvantage of centralized PFC is that the distribution lines of the installation, downstream of the PFC device, must be dimensioned taking into account the full reactive power required by the loads. 3.3 Circuit-breakers for the protection and switching of capacitor banks The circuit-breakers for the protection and switching of capacitor banks in LV shall: 1. withstand the transient currents which occur when connecting and disconnecting the banks. In particular, the instantaneous magnetic and electronic releases shall not trip due to these peak currents; 2. withstand the periodic or permanent overcurrents due to the voltage harmonics and to the tolerance (+15%) of the rated value of capacity; 3. perform a high number of no-load and on-load operations, also with high frequency; 4. be coordinated with any external device (contactors). Furthermore, the making and breaking capacity of the circuit-breaker must be adequate to the short- circuit current values of the installation. Standards IEC 60831-1 and 60931-1 state that: - the capacitors shall normally function with an effective current value up to 130% of their rated current Irc (due to the possible presence of voltage harmonics in the network); - a tolerance of 10% on the capacitance for banks up to 100 kvar and of 5% for banks exceeding 100 kvar is admited.



相關(guān)產(chǎn)品