產(chǎn)品展示
聯(lián)系我們
聯(lián)系人:麥女士
手機(jī):+86 15270269218
電話:
Q Q:3136378118
郵箱:stodcdcs@gmail.com
地址:江西省九江市瑞昌市東益路23號賽湖農(nóng)商城401號
PCI-6510
顯示/調(diào)整元件(續(xù))將卡上的DIL開關(guān)設(shè)置分配給閥門類型(另請參見印刷電路板上的符號)“Zw”(R130)和“Gw”電位計(jì)的含義:? 通過“Zw”(R130)電位計(jì)設(shè)置先導(dǎo)電流-順時(shí)針旋轉(zhuǎn)→ 先導(dǎo)電流增加–逆時(shí)針旋轉(zhuǎn)→ 導(dǎo)頻電流降低? 使用“Gw”電位計(jì)設(shè)置大命令值–順時(shí)針旋轉(zhuǎn)→ 命令值增加–逆時(shí)針旋轉(zhuǎn)→ 將命令值1)減小到部件系列5X注意事項(xiàng)(X):對于VT-VSPA1-1型(部件系列10),必須將BR22開關(guān)設(shè)置為“ON”,并且必須將“R130”電位計(jì)旋轉(zhuǎn)到左止點(diǎn),以設(shè)置正確的特性曲線。對于VT-VSPA1-1型(來自組件系列11)和VT-VSPA1K-1型,開關(guān)S21和S22沒有任何作用。無需操作“Zw”電位計(jì)。閥門類型設(shè)置:S15。。。S17(BR15…BR17)S21。。。S27(BR21…BR27)設(shè)置對所有閥門類型有效:S11。。。S14(BR11…BR14)DBE(M)T、DBE(M)30、DRE(M)30、3DRE(M)10 1、3DRE(M)16 1)、DBEP6A、DBEP6B、3DREP6A、3DREP6B泵在123456 7上的斜坡時(shí)間DRE(M)10-5X、DRE(M)20-5X在123456 7上的命令值2 DBE(M)10-5X、DBE(M)20-5X、3DRE(M)10P-6X、3DRE(M)16X P-6X,ZDRE10,(Z)DBE6在1 2 3456 7 1 2 3456 7在X DRE6上,ZDRE6 ON 1 2 3456 7 1 2 3456 7 ON X 0…20 mA ON 1 2 3456 7 4…20 mA ON 1 2 3456 7 5 s 1 s ON 1 2 3456 7+10 V ON 1 2 3456 7



Display/adjustment elements (continued) Assignment of the DIL switch settings on the card to the valve types (see also sign on the printed circuit board) Meaning of the "Zw" (R130) and "Gw" potentiometers: ? Pilot current setting by means of the "Zw" (R130) potentiometer – Clockwise rotation → increase in pilot current – Counterclockwise rotation → reduction of pilot current ? Setting of the max. command value using the "Gw" potentiometer – Clockwise rotation → increase in command value – Counterclockwise rotation → reduction of command value 1) To component series 5X Notice (X): With type VT-VSPA1-1 (component series 10), the BR22 switch must be set to "ON" and the "R130" potentiometer must be rotated to the left stop in order to set the correct characteristic curve. With type VT-VSPA1-1 (from component series 11) and type VT-VSPA1K-1, switches S21 and S22 do not have any effect. The "Zw" potentiometer does not have to be operated. Setting for valve types: S15 ... S17 (BR15 ... BR17) S21 ... S27 (BR21 ... BR27) Setting valid for all valve types: S11 ... S14 (BR11 ... BR14) DBE(M)T, DBE(M)30, DRE(M)30, 3DRE(M)10 1), 3DRE(M)16 1), DBEP6A, DBEP6B, 3DREP6A, 3DREP6B Pumps ON 1 2 3456 7 ON 1 2 3456 7 Ramp time DRE(M)10-5X, DRE(M)20-5X ON 1 2 3456 7 1 2 3456 7 ON X Command value 2 DBE(M)10-5X, DBE(M)20-5X, 3DRE(M)10P-6X, 3DRE(M)16P-6X, ZDRE10, (Z)DBE6 ON 1 2 3456 7 1 2 3456 7 ON X DRE6, ZDRE6 ON 1 2 3456 7 1 2 3456 7 ON X 0 … 20 mA ON 1 2 3456 7 4 … 20 mA ON 1 2 3456 7 5 s 1 s ON 1 2 3456 7 +10 V ON 1 2 3456 7
相關(guān)產(chǎn)品