聯(lián)系人:麥女士
手機(jī):+86 15270269218
電話:
Q Q:3136378118
郵箱:stodcdcs@gmail.com
地址:江西省九江市瑞昌市東益路23號(hào)賽湖農(nóng)商城401號(hào)
MAC90B-0-PD-1-B?/110-A-0/J1000
為每個(gè)電機(jī)/驅(qū)動(dòng)器文件指定了環(huán)境和安裝條件選擇列表。請(qǐng)參閱文件“ECODRIVE Servodrives DKC with MKD-選擇列表-選擇列表適用于給定的環(huán)境和安裝條件(見(jiàn)圖4-9)。對(duì)于不同的條件,根據(jù)圖表(見(jiàn)圖4-8)減少短期工作扭矩. 如果同時(shí)出現(xiàn)偏離環(huán)境溫度和更高安裝高度的情況,則必須將兩個(gè)荷載系數(shù)相乘。DG0200.fh5安裝標(biāo)高較高的荷載荷載系數(shù)環(huán)境溫度°C 1000 2000 3000 4000 5000 0,6 0,8 1 0,6 0,8 1 0 40 45 50 55 0安裝海拔高度米安裝標(biāo)高較高的荷載系數(shù)荷載圖4-8:荷載利用率作為一個(gè)值取決于環(huán)境溫度和安裝海拔高度Symbol+55內(nèi)部鼓風(fēng)機(jī)冷卻塔,高°C TUM°C+0+45 TL°C-30+85 m 1000%95 g/m 25 3 IP20,符合EN 60529=DIN VDE 0470-1-1992(IEC 529-1989)控制柜中的固定使用m kg 4.4 TB0204。fh5裝置非導(dǎo)電污垢污染,無(wú)冷凝MDN和MKB的選擇數(shù)據(jù)中所示的值,在+45至+55°C的范圍內(nèi),每升高一°C,下降2%。名稱環(huán)境和安裝條件冷卻功率段的大允許環(huán)境溫度(標(biāo)稱數(shù)據(jù)減少)允許環(huán)境溫度(標(biāo)稱數(shù)據(jù)存儲(chǔ)和運(yùn)輸)大安裝標(biāo)高(標(biāo)稱數(shù)據(jù)大允許相對(duì)濕度大允許濕度)污染防護(hù)等級(jí)重量



Ambient and installation conditions Selection lists are specified for each motor/drive documentation. Please refer to the documentation "ECODRIVE Servodrives DKC with MKD - Selection Lists - The selection lists apply within the given ambient and installation conditions (see Fig. 4-9). For different conditions, the short-term operating torque is reduced according to the diagrams (see Fig. 4-8). If deviating ambient temperatures and higher installation altitudes occur simultaneously, both load factors must be multiplied. DG0200.fh5 Load with higher installation elevations Load factor Ambient temperature in °C 1000 2000 3000 4000 5000 0,6 0,8 1 0,6 0,8 1 0 40 45 50 55 0 Installation altitude meters above sea level Load factor Load with higher ambient temperatures Fig. 4-8: Load utilization as a value dependent upon ambient temperature and installation altitude Symbol +55 internal blower cooling TUM,MAX °C TUM °C +0...+45 TL °C -30...+85 m 1000 % 95 g/m 25 3 IP20, as per EN 60529 = DIN VDE 0470-1-1992 (IEC 529-1989) stationary use in control cabinets m kg 4.4 TB0204.fh5 Unit Non-conductive dirt contamination, no condensation The values indicated in the selection data for MDN and MKB, drop in the range of +45 to +55°C by 2% per °C of rise in temperature. Designation Ambient and installation conditions Cooling the power section Max. permissible ambient temperature with reduced nominal data Permissible ambient temperature with nominal data Storage and transport temperature Max. installation elevation with nominal data Max. permissible relative humidity Max. permissible absolute humidity Degree of contamination Protection category Weight
-
MAC90C-0-GD-C-110-?A-0/MR119/5001外觀授權(quán)
-
MAC071C-0-NS-4H?C/095-B-0/WI518?LV重量顏色
-
MAC090B-0-PD-4-?C/110-A-0/WI/52?0LV-/S005外觀授權(quán)
-
MAC090C-1-GD-1-?B/110-A-0/-1012?50重量顏色
-
MAC90C-0-KD-3-C?.110-A-D.S001產(chǎn)品尺寸
-
MAC90A-1-RB-1-B?/110-A-1/J625速度數(shù)量
-
MAC112D-0-ED-1-?B/130-A-0/J1250?/S05產(chǎn)品尺寸
-
MAC093C-2-FS-4-?C-110A-0-WI520L?X-S001速度數(shù)量