PXI-6733使用手冊(cè)
PXI-6733使用手冊(cè)
PXI-6733使用手冊(cè)
PXI-6733使用手冊(cè)
PXI-6733使用手冊(cè)
PXI-6733使用手冊(cè)

型號(hào):PXI-6733

類別:NI

聯(lián)系人:麥女士

手機(jī):+86 15270269218

電話:+86 15270269218

Q Q:3136378118

郵箱:stodcdcs@gmail.com

地址:江西省九江市瑞昌市東益路23號(hào)賽湖農(nóng)商城401號(hào)


在線咨詢


PXI-6733
本章介紹您的PCI/PXI-6711/6713設(shè)備,列出您的
需要開始,描述可選軟件和可選設(shè)備,
并解釋了如何打開6711/6713設(shè)備的包裝。
關(guān)于6711/6713設(shè)備
感謝您購買National Instruments 6711/6713設(shè)備。你的
6711/6713設(shè)備是一種完全即插即用、模擬輸出、數(shù)字和
PXI/PCI/CompactPCI的定時(shí)輸入/輸出設(shè)備。6711/6713設(shè)備
每個(gè)通道具有12位數(shù)模轉(zhuǎn)換器(DAC),具有
電壓輸出的更新速率高達(dá)毫秒/秒/通道,八行
TTL兼容數(shù)字輸入/輸出,兩個(gè)24位計(jì)數(shù)器/定時(shí)器用于定時(shí)輸入/輸出。
6711設(shè)備具有四個(gè)電壓輸出通道,而6713
該設(shè)備具有八個(gè)電壓輸出通道。因?yàn)?711/6713
該設(shè)備沒有DIP開關(guān)、跳線或電位計(jì),很容易
軟件配置和校準(zhǔn)。
6711/6713設(shè)備是一種完全無開關(guān)、無跳線的數(shù)據(jù)傳輸設(shè)備
PXI/PCI/CompactPCI的采集(DAQ)設(shè)備。此功能是
由國(guó)家儀器公司的MITE總線接口芯片實(shí)現(xiàn)
將設(shè)備連接到PCI I/O總線。MITE實(shí)現(xiàn)PCI
本地總線規(guī)范,以便中斷和基本內(nèi)存地址
是否配置了所有軟件。
6711/6713設(shè)備使用National Instruments DAQ-STC系統(tǒng)
用于時(shí)間相關(guān)功能的定時(shí)控制器。DAQ-STC包括
控制模擬輸入、模擬輸出和
通用計(jì)數(shù)器/計(jì)時(shí)器功能。這些組共包括
七個(gè)24位和三個(gè)16位計(jì)數(shù)器,大定時(shí)分辨率為
50納秒。DAQ-STC的模擬輸入部分未被
6711/6713.
通常,對(duì)于其他DAQ設(shè)備,您無法輕松同步多個(gè)
測(cè)量功能適用于公共觸發(fā)器或計(jì)時(shí)事件。這個(gè)
PCI-6711/6713設(shè)備具有實(shí)時(shí)系統(tǒng)集成(RTSI)總線
解決此問題。RTSI總線由我們的RTSI總線接口和
帶狀電纜,用于在多個(gè)功能之間路由定時(shí)和觸發(fā)信號(hào)
一章導(dǎo)言
PCI/PXI-6711/6713用戶手冊(cè)1-2©美國(guó)國(guó)家儀器公司
在計(jì)算機(jī)中多達(dá)五個(gè)DAQ設(shè)備上。如果您正在使用
PXI-6711/6713在PXI機(jī)箱中,RTSI線路,稱為PXI觸發(fā)總線,
是背板的一部分,因此不需要RTSI電纜
PXI上的系統(tǒng)觸發(fā)和定時(shí)。
6711/6713裝置的詳細(xì)規(guī)格見附錄A,
規(guī)范。
PXI-6733使用手冊(cè) PXI-6733使用手冊(cè) PXI-6733使用手冊(cè)
This chapter describes your PCI/PXI-6711/6713 device, lists what you need to get started, describes the optional software and optional equipment, and explains how to unpack your 6711/6713 device. About the 6711/6713 Devices Thank you for buying a National Instruments 6711/6713 device. Your 6711/6713 device is a completely Plug and Play, analog output, digital, and timing I/O device for PXI/PCI/CompactPCI. The 6711/6713 device features a 12-bit digital-to-analog converter (DAC) per channel with update rates up to Ms/S/channel for voltage outputs, eight lines of TTL-compatible digital I/O, and two 24-bit counter/timers for timing I/O. The 6711 device features four voltage output channels, while the 6713 device features eight voltage output channels. Because the 6711/6713 device has no DIP switches, jumpers, or potentiometers, it is easily software-configured and calibrated. The 6711/6713 device is a completely switchless and jumperless data acquisition (DAQ) device for the PXI/PCI/CompactPCI. This feature is made possible by the National Instruments MITE bus interface chip that connects the device to the PCI I/O bus. The MITE implements the PCI Local Bus Specification so that the interrupts and base memory addresses are all software configured. The 6711/6713 device uses the National Instruments DAQ-STC system timing controller for time-related functions. The DAQ-STC consists of three timing groups that control analog input, analog output, and general-purpose counter/timer functions. These groups include a total of seven 24-bit and three 16-bit counters and a maximum timing resolution of 50 ns. The analog input section of the DAQ-STC is unused by the 6711/6713. Often with other DAQ devices, you cannot easily synchronize several measurement functions to a common trigger or timing event. The PCI-6711/6713 device has the Real-Time System Integration (RTSI) bus to solve this problem. The RTSI bus consists of our RTSI bus interface and a ribbon cable to route timing and trigger signals between several functions Chapter 1 Introduction PCI/PXI-6711/6713 User Manual 1-2 © National Instruments Corporation on as many as five DAQ devices in your computer. If you are using the PXI-6711/6713 in a PXI chassis, RTSI lines, known as the PXI trigger bus, are part of the backplane, therefore you do not need the RTSI cable for system triggering and timing on the PXI. Detailed specifications of the 6711/6713 device are in Appendix A, Specifications.
 